now working with multiple active busses.
Removed commented out test code and put a fix in for for
the filters list not having its capacity properly reserved
in recalcOverwrite so multiple entries of the same message
show up in the filtered view
No longer tossing partial frames, saving the data to concat with future data.
On startup there can be some data loss, but after it gets rolling there is none.
Added rough provision to ensure the buffer doesn't get filled with bad data, but
the decodeFrames recursive calls do a pretty good job of getting rid of it so I
haven't seen the buffer grow after millions of frames coming over a UDP-based VPN.
Sometimes when opening socketcand 1 or more busses won't start right and there's a ton of debug data saying "received datagramm: ...."
It seems to happen because the switch to RAW mode is in progress and we receive the OK with a frame in the same datagramm and we don't parse the OK out of the string
but rather expect the whole string to just be OK. Offending code is in socketcand.cpp SocketCANd::procRXData line 386
Fixed by looking to see if the < ok > message was at index 0 of the incoming message...could also look for it elsewhere (as in index != -1), but not sure if necessary