There are a TON of explorations I did here, many may be unnecessary, but this is a stake in the ground.
The main issue was the strange queue logic in canconmanager::sendFrame which puts the tx data in the rx
queue so it will show up in the displayed data. It caused SIGABRT and SIGSEG to show up everywhere.
It is NOT fixed yet, but TX works over the wire you just can't see it in the tableview.
I thought at first it was only when overwrite data was active, so I put in a a pile of changes to keep
frames and filtered frames as two seperate copies of data where frames was always complete and filtered
was only what was seen in the mainwindow. It made it so the graphing window would work with overwrite
data active which is an improvement. I wouldn't roll these changes back. Because of these changes I
had to update the frame sorting code adjust the refresh function in canframemode.cpp
I also thought it was related to UI updates, but its not, that's been confirmed.
I put a mutex around the custom sender tick timer so that the 1ms timer wouldn't re-enter its callback.
This didn't fix the crash, but it sure seems to make a lot of sense, and the way I did it no elasped
time is lost for tracking purposes, and in reality theres no way 1ms was consistent anyway.
I put a mutex around the shrinking of frames and filteredframes to make sure we weren't deleting at
the same time as accessing, but honestly we acccess those lists in many places without semaphores so
that probably did nothing.
Fixed a bug in FrameSenderWindow:DoModifiers that was improperly parsing and sometimes crashing when
looking for the ~ operator before a symbol.
Also added some minor work to keep row expansion functioning when changing filters or sorting. Need
to make some tweaks so it stops trying so hard when overwrite is not active
Theres also code in main.c taht makes debugging output super verbose.
Committing now to start cleanup
all. More development needed but this is a start. Also added ability
to set serial speed and bus speed in the device setup which may be
useful for other connection devices too.
now working with multiple active busses.
Removed commented out test code and put a fix in for for
the filters list not having its capacity properly reserved
in recalcOverwrite so multiple entries of the same message
show up in the filtered view
No longer tossing partial frames, saving the data to concat with future data.
On startup there can be some data loss, but after it gets rolling there is none.
Added rough provision to ensure the buffer doesn't get filled with bad data, but
the decodeFrames recursive calls do a pretty good job of getting rid of it so I
haven't seen the buffer grow after millions of frames coming over a UDP-based VPN.
Sometimes when opening socketcand 1 or more busses won't start right and there's a ton of debug data saying "received datagramm: ...."
It seems to happen because the switch to RAW mode is in progress and we receive the OK with a frame in the same datagramm and we don't parse the OK out of the string
but rather expect the whole string to just be OK. Offending code is in socketcand.cpp SocketCANd::procRXData line 386
Fixed by looking to see if the < ok > message was at index 0 of the incoming message...could also look for it elsewhere (as in index != -1), but not sure if necessary